AdobeStock_374980449.jpeg

Hotels

At Biddle, we are renowned for our commitment to high-quality heating and cooling solutions, meticulously tailored for the hotel industry.

Spatial constraints and access for maintenance can significantly influence system performance and noise levels. Our solutions are designed to minimise downtime whilst enhancing guest comfort and seamlessly integrating with your hotel’s architectural and operational needs.

From the entrance to guest rooms, meeting rooms, and reception areas, our solutions prioritise efficiency, ease of use, and reliability, ultimately reducing operational costs and preventing revenue loss due to room unavailability.

Air Curtains for Hotel Entrances

Our air curtains are engineered to minimise heat loss, maintain consistent indoor temperatures, and reduce energy costs. Ideal for any weather condition, they ensure a welcoming atmosphere right at the entrance — making first impressions count.

If you are wondering how air curtains work or how they can help you reduce your energy costs our team of experts can guide you through what you need.

sr-comfort.jpg

DecoQT: Climate Control as quiet as possible

Our DecoQT fan coil units are designed to provide efficient heating and cooling for hotel rooms of all sizes, at the lowest NR.

The DecoQT is designed to meet the aesthetic and functional requirements of the hotels. Featuring a sleek grille design, the units blend perfectly with any room décor while preventing direct visibility into the machinery, ensuring a harmonious look. Designed with a unique air inlet and discharge system that directs airflow towards the ceiling, DecoQT avoids draughts and ensures even temperature distribution. 

The units feature tool-free access for easy maintenance and quick filter changes, reducing downtime and operational costs.

Custom paint finishes on grilles are available to match any interior, making the DecoQT perfect for hotels looking to create a comfortable environment for their guests.

Unit Cut Out With Grill.jpg

Complete Heat Recovery

Maximise energy efficiency with our Air2Air Heat Recovery system, capturing up to 80% of heat from exhaust air to warm incoming fresh air, significantly reducing heating costs and improving your sustainability profile.

Solution Box.jpg

Hotel Climate Control: A Case Study

The Rembrandt Hotel in Knightsbridge, part of the Sarova Hotel Group, occupies a 1911 building originally planned as apartments for Harrods. Upgrading its guest-room air conditioning meant reusing the existing HVAC infrastructure, hitting a strict NR26 noise target and keeping disruption to guests to a minimum.

Working with the hotel’s design team, we supplied DecoQT 70 fan coil units with a five-row dual-purpose coil, giving precise room-by-room heating and cooling. Factory-fitted valve packs sped up installation and cut room downtime, while tool-free access to filters keeps maintenance quick. The result: bedside noise measured at just NR23 (28.9 dBA), comfortably beating the target, with simple touchscreen controls for guests.

IMG_5815.jpg

Meeting Rooms and Communal Areas Comfort

Biddle's ProAir Series fan coil units offer efficient and effective climate control solutions tailored to hotel rooms of all sizes. These systems are known for their quiet operation and energy efficiency, perfect for creating a comfortable guest environment. These units can be customised to meet your hotel's specific requirements, ensuring compliance with the rigorous standards of the UK specification market.

Our Comfort Circle2 Cassette Units are the perfect solution for hotels looking to provide comfortable heating and cooling in their reception, meeting rooms and eating areas. With a sleek and stylish design, these units provide both heating and cooling and can be installed easily into any ceiling, either free-hanging or recessed. Moreover, it is compatible with AHUs and HR systems. When integrated with AHUs, the air circulation is enhanced, guaranteeing a fresh and comfortable environment for gatherings of all sizes.

The large range of options available in Biddle's Fan Coil Units range allows customers to create a tailored climate solution for each individual space. 

EC fans run efficiently to minimise energy consumption, whilst also capable of running at variable speeds to keep noise levels and power usage to the minimum.

AdobeStock_266991118.jpeg

Why choose Biddle for HVAC in Hotels?

Our team is on hand to help you to select the best option for your requirements. We utilise selection tools to ensure we will provide you with the ideal solution, tailored to meet your specific requirements.

We streamline the ordering process, provide comprehensive technical data upfront, and commit to exceptional after-sales technical support to ensure smooth project execution and your complete satisfaction.

With Biddle, you're not just installing a system; you're investing in a seamless, supportive experience designed to exceed your expectations at every step of the way.

Hotel Climate Control FAQs

Fan coil units are a popular choice for hotel bedrooms because they’re quiet, you only need one unit to heat and cool, and each room can be controlled separately. Biddle’s DecoQT fan coil unit is designed for hotel rooms of all sizes, with a very low noise rating, a discharge that points towards the ceiling to avoid draughts, and a grille that hides the machinery.

The noise levels that an air conditioning unit will produce depend on fan speed, airflow design and how well the unit is insulated. Biddle’s fan coil units are lined internally and use EC fans that run at variable speeds, so they’re quieter and run efficiently. For quiet air conditioning in larger spaces, the ModulAir and ProAir Series can be specified to suit your project, and each unit’s NR figure is on its datasheet.

An air curtain above the entrance creates a barrier of air that helps keep conditioned air inside, even when the doors are being opened and closed all day. This keeps hotel lobbies at a steadier temperature and dramatically cuts the energy wasted heating or cooling air that ends up escaping. Biddle’s comfort air curtains are designed for hotel entrances of all sizes, so the first thing your guests experience as they enter is a comfortable environment.

A heat recovery system can help hotels lower their costs by capturing warmth from the stale air being extracted and using it to warm the fresh air coming in, rather than throwing that heat away. Biddle’s Air2Air Heat Recovery system recovers up to 80% of the heat from exhaust air, cutting hotels’ heating demands and supporting sustainability goals.

Ceiling cassette units suit hotel receptions, restaurants and meeting rooms because they sit out of the way and are still able to efficiently heat and cool. Biddle’s Comfort Circle2 cassette units can be free-hanging or recessed into the ceiling, and they also work as standalone units or alongside air handling units and heat recovery systems, improving air circulation when rooms fill up.

Book a Site Survey

St. Mary's Road, Nuneaton, Warwickshire, CV11 5AU,
United Kingdom

T: 02476 384233

E: sales@biddle-air.co.uk

Your details
Additional information

It is not our desire to SPAM you with daily emails but to keep you up to date with industry information, new products and offers.

GDPR Notice: Data submitted on this e-form will be securely passed onto our teams for response. Please see our GDPR policy for more information.